In many applications of perforated plate,
the estimated energy loss or pressure loss through perforated plates is one of the design considerations. The following pressure loss information was developed from a laboratory air flow system at Penn State University. The laboratory system maintained a non-swirling flow impacting perpendicularly on the sample. Various perforated thin gauge plates were inserted into a uniform velocity air flow stream.

• EMI Shielding
  Effectiveness


• Pressure Loss (Fluid)

• Pressure Loss (Air)

• Strength & Elasticity

• Formability

• Acoustical Applications
  (Tested)


• Acoustical Applications
  (Theory)

Pressure loss for ambient air flow was then measured at a series of velocities and reported as inches of water column loss for each flow. This data, therefore, presents the best flow condition value of loss. Pressure loss can be estimated beyond the range of the data on the basis of the ratio of the anticipated velocity to the highest tabulated velocity. This ratio squared multiplied by the tabulated pressure loss can be used to approximate the higher velocity loss.


Plate No Hole Dia "D (In)" Hole Dia "D (Mm)" Centers "S(In)" Centers "D (Mm)" Open area % Thickness "T (In)" Thickness "T (Mm)" T/D S/D
1 0.063 1.590 0.125 3.175 22.700 0.040 1.016 0.639 1.997
2 0.075 1.905 0.100 2.540 51.000 0.032 0.813 0.427 1.333
3 0.094 2.383 0.271 6.883 10.900 0.036 0.914 0.384 2.889
4 0.109 2.779 0.188 4.763 30.900 0.032 0.813 0.293 1.714
5 0.125 3.175 0.188 4.763 40.300 0.036 0.914 0.288 1.500
6 0.188 4.763 0.375 9.525 22.700 0.038 0.965 0.203 2.000
7 0.125 3.175 0.188 4.763 40.300 0.125 3.175 1.000 1.500

Pressure loss can be estimated from the tables for a different gas density by using the ratio of the anticipated gas density to the tabulated density as a multiplier of the noted loss.

Data was developed with the 0° being perpendicular to the flow and at angles of 22.5° and 45° away from perpendicular. Test plates #5 and #7 are presented to show effect having different thicknesses on air flow.



 